Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.763
Filtrar
1.
Molecules ; 29(7)2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38611949

RESUMO

Olibanum is a resinous traditional Chinese medicine that is directly used as a powder. It is widely used in China and is often combined with other traditional Chinese medicine powders to promote blood circulation and relieve pain, as well as to treat rheumatism, rheumatoid arthritis, and osteoarthritis. Powdered traditional Chinese medicine is often easily contaminated by microorganisms and 60Co irradiation is one of the good sterilization methods. Volatile organic compounds (VOCs) are the main active ingredient of olibanum. The aim of this study was to validate the optimum doses of 60Co irradiation and its effect on VOCs. 60Co irradiation was applied in different doses of 0 kGy, 1.5 kGy, 3.0 kGy, and 6.0 kGy. Changes in VOCs were detected using gas chromatography ion mobility spectrometry. A total of 81 VOCs were identified. The odor fingerprint results showed that, with an increase in irradiation dose, most of the VOCs of olibanum changed. Through principal component analysis, cluster analysis, and partial least squares discriminant analysis, it was demonstrated that, at 1.5 kGy, the impact of radiation on the VOCs of olibanum was minimal, indicating this is a relatively good irradiation dose. This study provides a theoretical basis for the irradiation processing and quality control of resinous medicinal materials such as olibanum and it also provides a good reference for irradiation technology development and its application to functional foods, thus making it both significant from a research perspective and useful from an application perspective.


Assuntos
Radioisótopos de Cobalto , Franquincenso , Compostos Orgânicos Voláteis , Espectrometria de Mobilidade Iônica , Cromatografia Gasosa-Espectrometria de Massas , Resinas Vegetais
2.
J Environ Radioact ; 275: 107426, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38522413

RESUMO

Echinacea purpurea marc (EPM), a residual of echinacea herb after the extraction process, was used as a natural low-cost sorbent for competitive sorption of 152+154Eu(III), 60Co(II) and 134Cs(I) radionuclides. The EPM was ground to prepare it for use in the sorption process. The variables influencing the sorption process were assessed, including pH, contact time, concentrations of metal ions, and temperature. EPM was characterized by different analytical instruments such as FTIR, SEM, XRD, and DTA/TGA. pH 4.0 was selected as the ideal pH value for competitive sorption of the studied ions. Adsorption kinetics data found that the sorption followed a pseudo-second-order model. The adsorption isotherm data was significantly better suited by the Langmuir isotherms in the case of Eu(III) ions while following Freundlich in the case of Co(II) and Cs(I) ions. Positive ΔHo values confirm the endothermic character of metal ion sorption onto EPM. The loading efficiencies of Eu(III), Co(II), and Cs(I) ions in the EPM column were 66.67%, 9.59%, and 4.81%, respectively. The EPM is a cost-effective and efficient separation of Eu(III) ions more than Cs(I) and Co(II) ions. Therefore, in the future, it will be a starting point for the separation of trivalent elements of lanthanide ions.


Assuntos
Radioisótopos de Césio , Radioisótopos de Cobalto , Adsorção , Radioisótopos de Césio/química , Radioisótopos de Césio/análise , Radioisótopos de Cobalto/química , Európio/química , Cinética , Poluentes Radioativos do Solo/análise
4.
Neurosurg Rev ; 47(1): 122, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38502283

RESUMO

This letter to the editor critiques a recent study evaluating the role of biologically effective dose (BED) in stereotactic radiosurgical thalamotomy for essential tremor (ET). The study, conducted retrospectively on 78 ET patients, demonstrates a significant correlation between BED and tremor improvement post-SRS. Moreover, the study suggests adjusting the prescribed dose rather than changing cobalt-60 sources to maintain treatment efficacy while minimizing toxicity. This suggestion aligns with previous research indicating an annual decrease in BED due to cobalt-60 decay. The letter emphasizes the importance of considering BED and cobalt-60 decay in optimizing treatment outcomes for ET patients undergoing stereotactic radiosurgery. Further research is recommended to explore innovative techniques for dose modulation in response to cobalt-60 decay and validate findings in larger cohorts.


Assuntos
Radioisótopos de Cobalto , Tremor Essencial , Radiocirurgia , Humanos , Tremor/cirurgia , Tremor Essencial/cirurgia , Radiocirurgia/métodos , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Resultado do Tratamento
5.
Bioconjug Chem ; 35(3): 412-418, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38411531

RESUMO

Cobalt-sarcophagine complexes exhibit high kinetic inertness under various stringent conditions, but there is limited literature on radiolabeling and in vivo positron emission tomography (PET) imaging using no carrier added 55Co. To fill this gap, this study first investigates the radiolabeling of DiAmSar (DSar) with 55Co, followed by stability evaluation in human serum and EDTA, pharmacokinetics in mice, and a direct comparison with [55Co]CoCl2 to assess differences in pharmacokinetics. Furthermore, the radiolabeling process was successfully used to generate the NTSR1-targeted PET agent [55Co]Co-NT-Sarcage (a DSar-functionalized SR142948 derivative) and administered to HT29 tumor xenografted mice. The [55Co]Co-DSar complex can be formed at 37 °C with purity and stability suitable for preclinical in vivo radiopharmaceutical applications, and [55Co]Co-NT-Sarcage demonstrated prominent tumor uptake with a low background signal. In a direct comparison with [64Cu]Cu-NT-Sarcage, [55Co]Co-NT-Sarcage achieved a higher tumor-to-liver ratio but with overall similar biodistribution profile. These results demonstrate that Sar would be a promising chelator for constructing Co-based radiopharmaceuticals including 55Co for PET and 58mCo for therapeutic applications.


Assuntos
Radioisótopos de Cobalto , Ciclotrons , Neoplasias , Humanos , Animais , Camundongos , Distribuição Tecidual , Xenoenxertos , Radioisótopos de Cobre/farmacocinética , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos/farmacocinética , Linhagem Celular Tumoral
6.
Radiat Prot Dosimetry ; 200(3): 221-228, 2024 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-37807769

RESUMO

This study aims to establish baseline micronucleus (MN) frequencies from various populations of residents in Vietnam and develop a 60Co dose-response curve for the cytokinesis-block micronucleus (CBMN) assay. Blood samples were exposed in vitro to a 60Co source at a dose rate of 275 mGy per min in a range of 0.1 to 4.0 Gy. MN background frequencies were 4.5 ± 3.2, 7.3 ± 4.6, 7.0 ± 3.8 and 13.1 ± 6.7 in 1000 binucleated (BN) cells for 96 healthy donors, 22 male radiation workers and 12 breast cancer patients, respectively. Blood samples from three healthy donors were used to generate the MN dose-response curve: y = C + (0.0496 ± 0.0069)D + (0.0143 ± 0.0026)D2. This curve was verified through an inter-laboratory comparison (RENEB ILC 2021). Our findings highlight the significance of the CBMN assay as an additional essential tool for biodosimetry in Vietnam.


Assuntos
Radioisótopos de Cobalto , Citocinese , Humanos , Masculino , Testes para Micronúcleos , Vietnã , Linfócitos
7.
J Appl Clin Med Phys ; 25(2): e14188, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37910646

RESUMO

This work presents the dosimetric characteristics of Total Body Irradiation (TBI) delivered using a dedicated Co-60 TBI unit. We demonstrate the ability to deliver a uniform dose to the entire patient without the need for a beam spoiler or patient-specific compensation. Full dose distributions are calculated using an in-house Monte Carlo treatment planning system, and cumulative dose distributions are created by deforming the dose distributions within two different patient orientations. Sample dose distributions and profiles are provided to illustrate the plan characteristics, and dose and DVH statistics are provided for a heterogeneous cohort of patients. The patient cohort includes adult and pediatric patients with a range of 132-198 cm in length and 16.5-37.5 cm in anterior-posterior thickness. With the exception of the lungs, a uniform dose of 12 Gy is delivered to the patient with nearly the entire volume receiving a dose within 10% of the prescription dose. Mean lung doses (MLDs) are maintained below the estimated threshold for radiation pneumonitis, with MLDs ranging from 7.3 to 9.3 Gy (estimated equivalent dose in 2 Gy fractions (EQD2 ) of 6.2-8.5 Gy). Dose uniformity is demonstrated across five anatomical locations within the patient for which mean doses are all within 3.1% of the prescription dose. In-vivo dosimetry demonstrates excellent agreement between measured and calculated doses, with 78% of measurements within ±5% of the calculated dose and 99% within ±10%. These results demonstrate a state-of-the-art TBI planning and delivery system using a dedicated TBI unit and hybrid in-house and commercial planning techniques which provide comprehensive dosimetric data for TBI treatment plans that are accurately verified using in-vivo dosimetry.


Assuntos
Planejamento da Radioterapia Assistida por Computador , Irradiação Corporal Total , Adulto , Humanos , Criança , Irradiação Corporal Total/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioisótopos de Cobalto/uso terapêutico , Radiometria/métodos
8.
Forensic Sci Int ; 354: 111887, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38007870

RESUMO

Two commercially available portable Rapid DNA instruments were evaluated for their ability to process 1 µL and 10 µL saliva samples deposited on metal and plastic surfaces and contaminated with surrogates of cesium (Cs)-137, strontium (Sr)-90 and cobalt (Co)-60; radioactive materials potentially released during a nuclear weapon accident or a radiological dispersal device detonation. A comparable success rate was noted for both Rapid DNA instruments when considering the number of complete and balanced DNA profiles, the number of profiles with a minimum of 10 autosomal STR loci (out of 23 [FlexPlex™ 27] or 21 [GlobalFiler™ Express]), and the possibility to search a national DNA database in Canada and the United States. Cobalt had an adverse impact on the quality of the megaplex short tandem repeat (STR) DNA profiles derived on each instrument for two of the three contamination levels tested in this study, i.e., 0.05 M and 0.1 M as reflected by a reduced number of detected alleles and decreased profile peak heights. Strontium exhibited some adverse effect on the Rapid DNA results when used at the highest contamination level (0.1 M) whereas cesium had none. No new artifacts were observed in the Rapid DNA profiles of samples spiked with the non-radiogenic surrogates. Importantly, in the context of a radiological/nuclear (RN) event, the ANDE™ 6C offers the possibility to dispose of all radioactive materials associated with contaminated samples quickly using a chip on which all steps of the Rapid DNA process are performed whereas the RapidHIT™ ID accumulates radioactive materials for many days before disposal. An individual handling 25 samples in a week (5 per day) on the RapidHIT™ ID at a 30.5 cm distance with a 5 min exposure to the radioactive source estimated at every run would exceed the 0.042 µSv/5 min limit with gamma dose rates for Cs at 0.13 mSv and for Co at 3.8 mSv. Beta dose rates calculated for the surrogate isotopes at the three concentrations tested were also above the recommended radiation exposure limit of 1 mSv/yr (0.042 µSv/5 min). Various potential mechanisms of action behind the interference noted for Sr and Co at high concentrations are presented. These elements may play a role in the steps prior to PCR (at the DNA molecule by binding to bases or to phosphate groups), during PCR (at the DNA polymerase as cofactors for catalytic sites), or even during amplified DNA fragment detection (as fluorescence quenchers).


Assuntos
Impressões Digitais de DNA , Terrorismo , Impressões Digitais de DNA/métodos , Reação em Cadeia da Polimerase , Repetições de Microssatélites , Mucosa Bucal/química , DNA/análise , Radioisótopos de Cobalto/análise , Radioisótopos de Césio/análise , Radioisótopos de Estrôncio/análise
9.
Neurosurgery ; 94(3): 575-583, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-37796152

RESUMO

BACKGROUND AND OBJECTIVES: Stereotactic radiosurgery (SRS) marginal dose is associated with successful obliteration of cerebral arteriovenous malformations (AVM). SRS dose rate-how old the cobalt-60 sources are-is known to influence outcomes for some neurological conditions and benign tumors. The objective of this study was to determine the association between cobalt-60 treatment dose rate and cerebral AVM obliteration in patients treated with SRS. METHODS: We performed a retrospective cohort study of 361 patients undergoing 411 AVM-directed SRS treatments between 2005 and 2019 at a single institution. Lesion characteristics, SRS details, obliteration dates, and post-treatment toxicities were recorded. Univariate and multivariate regression analyses of AVM outcomes regarding SRS dose rate (range 1.3-3.7 Gy, mean = 2.4 Gy, median = 2.5 Gy) were performed. RESULTS: At 10 years post-SRS, 68% of AVMs were obliterated on follow-up imaging. Dose rates >2.9 Gy/min were found to be significantly associated with AVM obliteration compared with those <2.1 Gy/min ( P = .034). AVM size, biologically effective dose, and SRS marginal dose were also associated with obliteration, with obliteration more likely for smaller lesions, higher biologically effective dose, and higher marginal dose. Higher dose rates were not associated with the development of post-SRS radiological or symptomatic edema, although larger AVM volume was associated with both types of edema. CONCLUSION: Patients with cerebral AVMs treated with higher SRS dose rates (from newer cobalt-60 sources) experience higher incidences of obliteration without a significant change in the risk of post-treatment edema.


Assuntos
Radioisótopos de Cobalto , Malformações Arteriovenosas Intracranianas , Radiocirurgia , Humanos , Resultado do Tratamento , Estudos Retrospectivos , Radiocirurgia/efeitos adversos , Radiocirurgia/métodos , Malformações Arteriovenosas Intracranianas/patologia , Doxorrubicina , Edema/etiologia , Edema/cirurgia , Seguimentos
10.
J Environ Radioact ; 272: 107351, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38064934

RESUMO

The uptake and effects of stable Cs and Co on L.minor were extensively studied, together with the effects of gamma radiation using a 137Cs or 60Co source. Innovative is that we combined external irradiation (from 137Cs or 60Co sources) with the direct uptake of certain amounts of stable Cs or Co to simulate the impact of the same mass of a radioisotope compared with that of the stable element. Such approach allows to differentiate between chemo- and radiotoxicity of 137Cs or 60Co, permitting to study the 137Cs and 60Co uptake by L. minor without using high concentrations of these elements in solution. Our results indicate that radiotoxicity of both 137Cs and 60Co has a greater importance compared to their chemotoxicity. This was also supported by the independent action and concentration addition concepts. Both concepts resulted in a good prediction of the dose-response curve of the combination exposure. The maximal removal of 137Cs or 60Co per gram dry matter of L. minor was lower compared with the removal of the corresponding stable isotope. The toxicity of 60Co was higher compared to 137Cs based on EC50 values and uptake data. With respect to the effects on photosynthetic pigments, starch and soluble sugars contents, only starch increased in a concentration- and dose-dependent manner.


Assuntos
Araceae , Radioisótopos de Césio , Radioisótopos de Cobalto , Monitoramento de Radiação , Fotossíntese , Amido/farmacologia
11.
PLoS One ; 18(9): e0291344, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37713447

RESUMO

This study aims to observe the accelerated aging effect of 60Co gamma (γ) irradiation on poly (methyl methacrylate) (PMMA) under extreme conditions and determine the influence of different media states on aging. PMMA samples were prepared at room temperature under varying media conditions, including air and deionized water immersion. Then, the samples were irradiated with different doses (50, 250, 500, and 1000 KGy) of 60Co γ-rays. The compositional changes of the PMMA samples exposed to the rays at different periods were determined via Fourier transform infrared spectroscopy. The light transmission of the samples was characterized through ultraviolet-visible spectrophotometry, and the surface wettability of the samples was assessed via water contact angle measurements. Surface and microscopic changes in material morphology were analyzed using optical microscopy, ImageJ software, and scanning electron microscopy. Relative molecular mass and glass transition temperature were analyzed via gel permeation chromatography and differential scanning calorimetry. Thus, a comprehensive analysis of the effect of 60Co γ irradiation on the aging properties of PMMA was performed.


Assuntos
Radioisótopos de Cobalto , Polimetil Metacrilato , Materiais Biocompatíveis , Microscopia Eletrônica de Varredura
12.
Appl Radiat Isot ; 198: 110866, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37235985

RESUMO

A ground-level prototype system for low-background measurements was developed and tested. The system consists of a high-purity germanium (HPGe) detector used for detecting γ rays and coupled to a liquid scintillator (LS) used for detecting α and ß particles. Both detectors are surrounded by shielding materials and anti-cosmic detectors ("veto") used to suppress background events. The energy and timestamp of detected α, ß and γ emissions are recorded event-by-event and analyzed offline. By requiring timing coincidence between the HPGe and LS detectors, background events originating from outside the volume of the measured sample can be effectively rejected. The system performance was evaluated using liquid samples containing known activities of an α emitter (241Am) or a ß emitter (60Co) whose decays are accompanied by γ rays. The LS detector was found to provide a solid angle of almost 4π for α and ß particles. Compared to the traditional γ-singles mode, operating the system in coincidence mode (i.e., α-γ or ß-γ) reduced the background counts by a factor of ∼100. Consequently, the minimal detectable activity for 241Am and 60Co was improved by a factor of 9, being 4 mBq and 1 mBq for an 11-d measurement, respectively. Furthermore, by applying a spectrometric cut in the LS spectrum that corresponds to α emission from 241Am, a background reduction factor of ∼2400 (compared to γ-singles mode) was achieved. Beyond low-background measurements, this prototype exhibits additional compelling features, such as the ability to focus on certain decay channels and study their properties. This concept for a measurement system may be of interest to laboratories that monitor environmental radioactivity, studies involving environmental measurements and/or trace-level radioactivity.


Assuntos
Germânio , Espectrometria gama , Espectrometria gama/métodos , Raios gama , Radioisótopos de Cobalto
13.
Med Phys ; 50(7): 4466-4479, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37086040

RESUMO

PURPOSE: A novel compensator-based system has been proposed which delivers intensity-modulated radiation therapy (IMRT) with cobalt-60 beams. This could improve access to advanced radiotherapy in low- and middle-income countries. For this system to be clinically viable and to be adapted into the Radiation Planning Assistant (RPA), being developed to offer automated planning services in low- and middle-income countries, it is necessary to commission and validate it in a commercial treatment planning system (TPS). METHODS: The novel treatment device considered here employs a cobalt-60 source and nine compensators. Each compensator is produced by 3-D printing a thin plastic mold which is then filled on-demand within the machine with reusable 2-mm-diameter spherical tungsten balls. This system was commissioned in the Eclipse TPS and validation tests were conducted with Monte Carlo using Geant4 Application for Tomographic Emission for percentage depth dose, in-plane profiles, penumbra, and IMRT dose validation. And the American Association of Physicists in Medicine Task Group 119 benchmarking testing was performed. Additionally, compensator-based cobalt-60 IMRT plans were created for 46 head-and-neck cancer cases and compared to the linac-based volumetric modulated arc therapy (VMAT) plans used clinically, then dosimetric parameters were evaluated. Beam-on time for each field was calculated. In addition, the measurement was also performed in a limited environment and compared with the Monte Carlo simulations. RESULTS: The differences in percent depth doses and in-plane profiles between the Eclipse and Monte Carlo simulations were 0.65% ± 0.41% and 1.02% ± 0.99%, respectively, and the 80%-20% penumbra agreed within 0.46 ± 0.27 mm. For the Task Group 119 validation plans, all treatment planning goals were met and gamma passing rates were >95% (3%/3 mm criteria). In 46 clinical head-and-neck cases, the cobalt-60 compensator-based IMRT plans had planning target volume (PTV) coverages similar to linac-based VMAT plans: all dosimetric values for PTV were within 1.5%. The organs at risk dose parameters were somewhat higher in cobalt-60 compensator-based IMRT plans versus linac-based VMAT plans. The mean dose differences for the spinal cord, brain, and brainstem were 4.43 ± 1.92, 3.39 ± 4.67, and 2.40 ± 3.71 Gy, while those for the rest of the organs were <1 Gy. The average beam-on time per field was 0.42 ± 0.10 min for the 6 MV multi-leaf-collimator plans while those for the cobalt-60 compensator plans were 0.17 ± 0.01 and 0.31 ± 0.01 min at the dose rates of 350 and 175 cGy/min. There was a good agreement between in-plane profiles from measurements and Monte Carlo simulations, which differences are 1.34 ± 1.90% and 0.13 ± 2.16% for two different fields. CONCLUSIONS: A novel compensator-based IMRT system using cobalt-60 beams was commissioned and validated in a commercial TPS. Plan quality with this system was comparable to that of linac-based plans in all test cases with shorter estimated beam-on times. This system enables reliable, high-quality plans with reduced cost and complexity and may have benefits for underserved regions of the world. This system is being integrated into the RPA, a web-based platform for auto-contouring and auto-planning.


Assuntos
Radioterapia de Intensidade Modulada , Radioterapia de Intensidade Modulada/métodos , Radioisótopos de Cobalto/uso terapêutico , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica
14.
Radiat Oncol ; 18(1): 13, 2023 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-36670476

RESUMO

BACKGROUND: The purpose of this work was to obtain the dosimetric parameters of the new GZP3 60Co high-dose-rate afterloading system launched by the Nuclear Power Institute of China, which is comprised of two different 60Co sources. METHODS: The Monte Carlo software Geant4 and EGSnrc were employed to derive accurate calculations of the dosimetric parameters of the new GZP3 60Co brachytherapy source in the range of 0-10 cm, following the formalism proposed by American Association of Physicists in Medicine reports TG43 and TG43U1. Results of the two Monte Carlo codes were compared to verify the accuracy of the data. The source was located in the center of a 30-cm-radius theoretical sphere water phantom. RESULTS: For channels 1 and 2 of the new GZP3 60Co afterloading system, the results of the dose-rate constant (Λ) were 1.115 cGy h-1 U-1 and 1.112 cGy h-1 U-1, and for channel 3 they were 1.116 cGy h-1 U-1 and 1.113 cGy h-1 U-1 according to the Geant4 and EGSnrc, respectively. The radial dose function in the range of 0.25-10.0 cm in a longitudinal direction was calculated, and the fitting formulas for the function were obtained. The polynomial function for the radial dose function and the anisotropy function (1D and 2D) with a [Formula: see text] of 0°-175° and an r of 0.5-10.0 cm were obtained. The curves of the radial function and the anisotropy function fitted well compared with the two Monte Carlo software. CONCLUSION: These dosimetric data sets can be used as input data for TPS calculations and quality control for the new GZP3 60Co afterloading system.


Assuntos
Braquiterapia , Radiometria , Humanos , Dosagem Radioterapêutica , Radiometria/métodos , Software , Radioisótopos de Cobalto , Método de Monte Carlo , Braquiterapia/métodos , Anisotropia
15.
Int J Biol Macromol ; 229: 344-353, 2023 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-36586656

RESUMO

A sustainable and efficient nanobentonite@sodium alginate@oleylamine (Nbent@Alg@OA) nanocomposite has been successfully synthesized via coating reaction of nanobentonite (Nbent) with alginate (Alg) and oleylamine (OA). The nanocomposite has been characterized and examined for the adsorption of 60Co(II) and 152+154Eu(III) radionuclides from simulated radioactive waste solution. FT-IR, XRD, SEM, and HR-TEM techniques have been applied to confirm the structural and morphological characteristics of the Nbent@Alg@OA nanocomposite. The effects of various parameters, such as pH of the medium, initial concentration of the radionuclides, contact time, and temperature on the adsorption of 60Co(II) and 152+154Eu(III) radionuclides were investigated by the batch adsorption technique. The results revealed that the optimum pH values for the adsorption of 152+154Eu (III) and 60Co (II) radionuclides were 4 and 5, respectively. The adsorption capacity of 152+154Eu(III) (65.6219 mg/g) was found greater than that of 60Co(II) (47.3469 mg/g). The adsorption process was found to be well described by the pseudo-second-order kinetic model. Furthermore, the equilibrium isotherm evaluation revealed that the Langmuir model was adequately matched with the adsorption data. According to the thermodynamic characteristics, the adsorption process was endothermic and spontaneous. Regeneration and reuse of Nbent@Alg@OA nanocomposite confirmed that the recycled nanocomposite was sufficiently efficient in several successive practical applications.


Assuntos
Nanocompostos , Poluentes Químicos da Água , Espectroscopia de Infravermelho com Transformada de Fourier , Adsorção , Alginatos/química , Radioisótopos de Cobalto , Nanocompostos/química , Poluentes Químicos da Água/química , Concentração de Íons de Hidrogênio , Cinética
16.
Radiat Prot Dosimetry ; 199(3): ncac280 262 269-276, 2023 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-36575963

RESUMO

In the ICRU Report 90, the uncertainty of the recommendation for ${{W}}_{{air}}$ was changed from 0.15 to 0.35%. The purpose of this study is to develop an absolute measurement system for ${{W}}_{{air}}$ in electrons with lower uncertainty using 60Co gamma rays. ${{W}}_{{air}}$ was determined by the ratio of the energy deposition to the number of ion pairs created in a given volume of air using a graphite calorimeter and a graphite-wall ionisation chamber. The obtained value for ${{W}}_{{air}}$ was 33.91 eV with a relative standard uncertainty of 0.08 eV (k = 1), and was in good agreement with the recommended value of the ICRU Report 90 (33.97 eV). Additionally, the uncertainty for ${{W}}_{{air}}$ obtained in this investigation is 0.23% and is comparable with that reported by Burns et al., which is the lowest uncertainty in recent studies determining ${{W}}_{{air}}$ In the future, the proposed system can be used to measure ${{W}}_{{air}}$ in high-energy electron beams.


Assuntos
Grafite , Radiometria , Raios gama , Radioisótopos de Cobalto , Ar
17.
Food Chem ; 399: 134013, 2023 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-36037695

RESUMO

Ovalbumin (OVA)-glucose mixture was treated with Co-60 irradiation at 0-25 kGy, and effects of irradiation on the glycation and allergenicity of OVA were investigated. Irradiation induced glycation between OVA and glucose, reflected in the significant increase of glycation sites from 3 to 14. Interestingly, OVA irradiated at 25 kGy had three new glycated peptides (568.782+, 739.382+ and 509.752+). The degree of substitution per peptide molecule (DSP) of glycated peptides exhibited different trends with increasing irradiation dose. Particularly, glycated peptides 17-26, 55-60, 263-267 and 368-375 showed markedly decreased DSP values after irradiation at 20 and 25 kGy, which could be caused by the generation of Maillard reaction products (MRPs). MS/MS spectra suggested that neutral loss occurred in glycated arginine, whose structure was similar to MRPs. The IgG- and IgE-binding abilities of OVA significantly decreased with increasing irradiation dose, indicating that the protein allergenicity was reduced.


Assuntos
Alérgenos , Radioisótopos de Cobalto , Alérgenos/química , Ensaio de Imunoadsorção Enzimática , Glucose , Ovalbumina/química , Peptídeos/química , Espectrometria de Massas em Tandem
18.
J Cancer Res Ther ; 19(Suppl 2): S477-S484, 2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38384008

RESUMO

ABSTRACTS: A key challenge in radiation therapy is to maximize the radiation dose to cancer cells while minimizing damage to healthy tissues. In recent years, the introduction of remote after-loading technology such as high-dose-rate (HDR) brachytherapy becomes the safest and more precise way of radiation delivery compared to classical low-dose-rate (LDR) brachytherapy. However, the axially symmetric dose distribution of HDR with single channel cylindrical applicator, the physical "dead-space" with multichannel applicators, and shielding material heterogeneities are the main challenges of HDR brachytherapy. Thus, this review aimed to quantitatively evaluate the dose enhancement factor (DEF) produced by high atomic number nanoparticles (NPs) which increases the interaction probability of photons mainly through the photoelectric effect induced in the great number of atoms contained in each nanoparticle. The NPs loaded to the target volume create a local intensification effect on the target tissue that allows imparting the prescribed therapeutic dose using lower fluxes of irradiation and spare the surrounding healthy tissues. An electronic database such as PubMed/Medline, Embase, Scopus, and Google Scholar was searched to retrieve the required articles. Unpublished articles were also reached by hand from available sources. The dose is increased using the high atomic number of nanoparticle elements under the high dose iridium radionuclide whereas the cobalt-60 radionuclide source did not. However, much work is required to determine the dose distribution outside the target organ or tumor to spare the surrounding healthy tissues for the iridium source and make compressive work to have more data for the cobalt source.


Assuntos
Braquiterapia , Radioisótopos de Cobalto , Nanopartículas , Neoplasias , Humanos , Irídio , Radioisótopos , Radioisótopos de Irídio/uso terapêutico , Braquiterapia/efeitos adversos , Neoplasias/radioterapia , Neoplasias/tratamento farmacológico , Dosagem Radioterapêutica
19.
Radiat Oncol ; 17(1): 206, 2022 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-36514118

RESUMO

BACKGROUND: High-dose-rate (HDR) intracavitary-interstitial brachytherapy (IC-ISBT) is an effective treatment for bulky, middle, and advanced cervical cancer. In this study, we compared the differences between 60Co and 192Ir HDR IC-ISBT plans in terms of radiobiological and dosimetric parameters, providing a reference for clinical workers in brachytherapy. METHODS: A total of 30 patients with cervical cancer receiving HDR IC-ISBT were included in this study, and IC-ISBT plans for each individual were designed with both 60Co and 192Ir at a prescribed dose of CTV D90 = 6 Gy while keeping the dose to OARs as low as possible. Physical dose and dose-volume parameters of CTV and OARs were extracted from TPS. The EQD2, EUBED, EUD, TCP, and NTCP were calculated using corresponding formulas. The differences between the 60Co and 192Ir IC-ISBT plans were compared using the paired t-test. RESULTS: In each patient's 60Co and 192Ir IC-ISBT plan, the average physical dose and EQD2 of 60Co were lower than those of 192Ir, and there were statistically significant differences in D2cc and D1cc for the OARs (p < 0.05); there were statistically significant differences in D0.1 cc for the bladder (p < 0.05) and no significant differences in D0.1 cc for the rectum or intestines (p > 0.05). The EUBED ratio (60Co/192Ir) at the CTV was mostly close to 1 when neither 60Co or 192Ir passed their half-lives or when both passed two half-lives, and the difference between them was not significant; at the OARs, the mean value of 60Co was lower than that of 192Ir. There was no statistical difference between 60Co and 192Ir in the EUD (93.93 versus 93.92 Gy, p > 0.05) and TCP (97.07% versus 97.08%, p > 0.05) of the tumors. The mean NTCP value of 60Co was lower than that of 192Ir. CONCLUSIONS: Considering the CTV and OARs, the dosimetric parameters of 60Co and 192Ir are comparable. Compared with 192Ir, the use of 60Co for HDR IC-ISBT can ensure a similar tumor control probability while providing better protection to the OARs. In addition, 60Co has obvious economic advantages and can be promoted as a good alternative to 192Ir.


Assuntos
Braquiterapia , Neoplasias do Colo do Útero , Feminino , Humanos , Neoplasias do Colo do Útero/radioterapia , Neoplasias do Colo do Útero/patologia , Radioisótopos de Cobalto/uso terapêutico , Dosagem Radioterapêutica , Radioisótopos de Irídio/uso terapêutico , Órgãos em Risco/patologia , Planejamento da Radioterapia Assistida por Computador
20.
Radiat Res ; 198(6): 599-614, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-36279323

RESUMO

Well-characterized and validated animal models are required for the development of medical countermeasures (MCMs) for acute radiation syndrome to mitigate injury due to high doses of total- or partial-body irradiation. Animal models used in MCM development must reflect a radiation dose- and time-dependent relationship, clinical presentation, and pathogenesis of organ injuries in humans. The objective of the current study was to develop the lethality curve for the Armed Forces Radiobiology Research Institute high level cobalt-60 gamma-radiation source in nonhuman primates (NHPs) after total-body irradiation. A dose-response relationship was determined using NHPs (rhesus macaques, N = 36, N = 6/radiation dose) irradiated with 6 doses in the range of 6.0 to 8.5 Gy, with 0.5 Gy increments at a dose rate of 0.6 Gy/min. Animals were provided subject-based supportive care including blood transfusions and were monitored for 60 days postirradiation. Survival was the primary endpoint of the study and the secondary endpoint included hematopoietic recovery. The lethality curve suggested LD30/60, LD50/60, and LD70/60 values as 5.71, 6.78, and 7.84 Gy, respectively. The results of this study will be valuable to provide specific doses for various lethalities of 60Co-gamma radiation to test radiation countermeasures in rhesus macaques using subject-based supportive care including blood transfusion.


Assuntos
Radioisótopos de Cobalto , Raios gama , Exposição à Radiação , Animais , Raios gama/efeitos adversos , Macaca mulatta , Radiobiologia , Exposição à Radiação/efeitos adversos , Radioisótopos de Cobalto/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...